ELTAKO TLZ12-8E-230V UC PDF

Manufacturer name, Eltako. Manufacturer number, TLZEV+UC. GTIN, Country of origin, Germany. Customs tariff number, gThe Standardg TLZ12 8E 23 V UC replaces the TLZ12N0 V and TLZ12 8E V+V uC. gThe Allrounderg TLZ12D 23 V UC replaces the TLZ12M V+V uC. g The Simpleg . Also visit TLZ12D V +UC. Eltako Staircase time switch TLZplus 1; 2; 3; 4 Matching products. Eltako Staircase time switchTLZ Manufacturer, Eltako. Manufacturer.

Author: Mozahn JoJocage
Country: Grenada
Language: English (Spanish)
Genre: Business
Published (Last): 18 April 2014
Pages: 227
PDF File Size: 3.53 Mb
ePub File Size: 20.72 Mb
ISBN: 889-6-68940-576-4
Downloads: 22571
Price: Free* [*Free Regsitration Required]
Uploader: Yozshushicage

The dimming speed is adjustable using the dimming speed rotary switch.

It switches the tlz21-8e-230v ballast with a bistable relay at the output EVG electronic ballast units. Switching operation for childrens rooms: A fold inrush current must be expected for electronic ballast devices.

Eltako Treppenlicht Zeitschalter Tlzev UC | eBay

With a double impulse the lighting is dimmed down from the current dimming position and finally switched off. Then additional standby loss of only 0. The buttons are blue. If the contact is used for controlling switching devices which do not perform zero passage switching themselves, N should not be connected because the additional closing delay otherwise causes the opposite effect. This can be of advantage for energy saving lamps because cold energy saving lamps require a higher minimum brightness as it will possibly be stored in Memory for warmer energy saving lamps.

Cumulative value in kWh. Individual special terms and conditions. It will be synchronised at first operation. If the function ESV eltao set the time ranges twhich can be set with the middle rotary switch are as follows: G6Accessory base load A base load is used if loads cannot be detected due to their capacitance but are meant to switchon the line voltage. The energy consumption indicator EVA12 uses the current between uf and output to measure active sltako in the same way as a single-phase energy meter.

  KONGRESI I BERLINIT PDF

As the rst leading manufacturer of staircase time switches, we produce new devices with ttlz12-8e-230v for energy saving lamps. Press the MODE key again to restart the input cycle.

Soluções Eléctricas

Without N connection, therefore suitable for mounting directly behind the push-button light switch or light switch, even if no N wire is available. Zero passage switching with soft start and soft OFF to protect lamps. This simulates twilight at the beginning of the time window in order to open all shading elements and at the same time all sensors are switched off. With priority because these control inputs cannot be overridden by other control inputs as long as the central control contact is closed.

When the control contact light switch is closed the operating delay AV starts if not set ‘0 minutes’on time-out the fan is switched on. With a double impulse the lighting is dimmed down from the current dimming position to the minimum brightness level and switched off.

Typical connection Side view For installation. With the rotary switch WA automatic reversal is controlled: Field 2 can display up to 99 accumulated operating years T2. Universal dimmer switch for R, L and C loads up to watt, depending on ventilation conditions. Universal control voltage input 8 to V UC, electrically isolated from the V supply voltage and switching voltage.

  ADIOS CORDERA PDF

Connections on the low voltage side: With one LED connected in oating mode, in one of the colours: The timing relay is now ready to operate. This impulse group switch serves to implement commands generated by the sensor relays or by switches and push-buttons and controls a V motor for a shading element or a roller shutter.

With three switch positions: The flashing decimal point is dependent on power consumption and indicates that power is being consumed. If a new small load is switched eltakl for more than 24 hours, the total current drawn by the monitored circuit is less than mA, the FR12 is set to A mode and in the meantime the light has been switched on and off, the new load is learned in and the conductor is switched off. The LED behind the rotary switch indicates when the brightness value is uv.

This pulse sequence is evaluated in a LRW12D universal sensor relay connected in series. Time setting between 0.

广州市继电器厂家_供应ELTAKO继电器_一呼百应网

Incandescent lamp load up to W. This display refers to the cumulative value in field 3.

Only dimmer switches with an additional ESL marking are optimized for dimmable energy saving lamps.